MTI Instruments AccumeasureÊý×ÖµçÈÝϵͳDϵÁÐGen 3

·¢²¼Ê±¼ä£º2021-03-15 17:15:58     ä¯ÀÀ£º1529

MTI Instruments AccumeasureDµçÈÝÊ½Î»ÒÆ´«¸ÐÆ÷ϵÁзŴóÆ÷ÊÇÒ»¸ö¸ïÃüÐÔµÄÉè¼Æ·½°¸¡£ËüÔËÓÃÍ»ÆÆÐÔ¼¼Êõ£¬½«¸ß¿É¿¿µÄµçÈݵ糡¼ì²â£¨Î»ÒÆ£©Ö±½Óת»¯³É¸ß¾«¶ÈµÄ24λÊý×Ö¶ÁÊý£¬´Ó¶ø¾«È·²âÁ¿Î»Öᢺñ¶È¡¢Ô˶¯ºÍÕ𶯡£

MTI InstrumentsµÄÐÂÐ͵çÈÝ·Å´óÆ÷½«Ì½Í·µçÈÝÖ±½Óת»»³ÉΪĿ±ê¼ä¾à£¨¾àÀ룩¡£ÕâÀàÖ±½Óת»»·½·¨Ïû³ýÁË´«Í³Ê½Ä£Äâ·Å´óÆ÷¼øÓÚÄ£ÄâÂ˲¨¡¢ÏßÐÔ»¯¡¢·¶Î§ÍØÕ¹ºÍͨµÀÇóºÍ¶øÔì³ÉµÄÎó²îÖµ£¬´Ó¶ø»ñÈ¡ºñ¶È»ò½×Ô¾¼ì²âÖµ¡£Æ¾½èAccumeasure DϵÁУ¬¶ÔÂ˲¨Æ÷µÄƵÂÊÏìÓ¦¡¢²ÉÑùÂÊ¡¢ÏßÐÔ»¯ºÍ̽ͷ·¶Î§ÊµÏÖÁËÊý×Ö¿ØÖÆ¡£ÕâÈ·±£ÁË×î׼ȷµÄÊý¾Ýץȡ¡¢ÎÞËð´¦ÀíºÍ¹ºÂò¶îÍâ²É¼¯Ó²¼þÅäÖõÄ×ÔÓÉȨ¡£

±ê×¼º¯ÊýÕý½»±àÂëÆ÷ÊäÈ룬¸ù¾ÝÎ»ÒÆ²âÁ¿ÖµÓë̽ͷλÖÃͬ²½£¬Ìṩ̽ͷλÖÃÐÅÏ¢ºÍÎ»ÒÆÐźţ¬Ìṩ¸÷ÖÖ¸÷Ñùµ¼µçºÍ°ëµ¼ÌåÄ¿±êµÄ׼ȷ±íÃæÂÖÀª¡£MTI InstrumentsµÄDigital AccumeasureµçÈÝÊ½Î»ÒÆ´«¸ÐÆ÷·Å´óÆ÷±ê×¼ÅäÖÃ24λUSB/ÒÔÌ«ÍøÊý×ÖÊä³ö¡£³ýÈ¥±ê×¼µÄÊý×ÖÊä³öÍ⣬ģÄâÊä³öÄ£ÐÍ»¹°üÀ¨Ä£ÄâÊä³ö¡£Á½ÕßÄܹ»Í¬Ê±ÔËÓá£ÕâÌØ±ðÊʺÏÓÚ±Õ»·Ó¦ÓóÌÐò»ò¼¯³É»¯µ½ÐèҪģÄâµÄ²Ù×÷ϵͳÖС£

ÌØÐÔ

ÕæÕýµÄÖ±½ÓÊý×ÖµçÈÝÎ»ÒÆ´«¸ÐÆ÷

µçÈÝÊ½Î»ÒÆ´«¸ÐÆ÷

¸ß´ï0.01%FSRÏßÐÔ¶È

ÑÇÄÉÃ×·Ö±æÂÊ

ÄÚÖÃÕý½»ÊäÈë

20Ks/s

È«²¿Í¨µÀ

ÎÞADC

¼ä¾àÏìÓ¦µÄ100%Êý×ÖÏßÐÔ»¯

ÎÞËð24λ´¦Àí

ºÍNILabVIEW?½Ó¿Ú

¿Éµ÷Êä³öÊý¾ÝËÙÂÊ

̽ͷÊý×Ö¶¨Ïà

¸¡°Ð¼ì²â

Êý¿Ø·¶Î§ÍØÕ¹¡¢Â˲¨ºÍÐÅºÅÆ½¾ù

USBºÍÒÔÌ«ÍøÊä³ö

Ä£ÄâÊä³ö

ÎÞÐè¶îÍâµÄ²É¼¯Ó²¼þÅäÖÃ

ÉîÛÚÊÐÁ¢Î¬´´Õ¹¿Æ¼¼ÓÐÏÞ¹«Ë¾£¬ÓÅÊÆÖ±½ÓÇþµÀÌṩMTI Instrument s¶©»õ·þÎñ£¬»¶Ó­×Éѯ¡£

ÏêÇéÁ˽âMTI Instrument sÇëµã»÷£º/brand/70.html

»òÁªÏµÎÒÃǵÄÏúÊÛ¹¤³Ìʦ£º0755-83642657   QQ: 2295048674

 Accumeasure D.png

P/N

Accuracy

Interface

Type

Frequency Response

8000-6454-100

0.01% FSR

USB

1-channel (SE)

User Selectable 50Hz to 5kHz

8000-6454-110

0.01% FSR

Analog and USB

1-channel (SE)

User Selectable 50Hz to 5kHz

8000-6454-200

0.01% FSR

USB

2-channel (SE)

User Selectable 50Hz to 5kHz

8000-6454-201

0.01% FSR

USB

2-channel (PP)

User Selectable 50Hz to 5kHz

8000-6454-202

0.01% FSR

USB

2-channel (180)

User Selectable 50Hz to 5kHz

8000-6454-210

0.01% FSR

Analog and USB

2-channel (SE)

User Selectable 50Hz to 5kHz

8000-6454-211

0.01% FSR

Analog and USB

2-channel (PP)

User Selectable 50Hz to 5kHz

8000-6454-212

0.01% FSR

Analog and USB

2-channel (180)

User Selectable 50Hz to 5kHz

8000-6454-300

0.01% FSR

USB

3-channel (SE)

User Selectable 50Hz to 5kHz

8000-6454-310

0.01% FSR

Analog and USB

3-channel (SE)

User Selectable 50Hz to 5kHz

8000-6454-400

0.01% FSR

USB

4-channel (SE)

User Selectable 50Hz to 5kHz

8000-6454-401

0.01% FSR

USB

4-channel (PP)

User Selectable 50Hz to 5kHz

8000-6454-402

0.01% FSR

USB

4-channel (180)

User Selectable 50Hz to 5kHz

8000-6454-410

0.01% FSR

Analog and USB

4-channel (SE)

User Selectable 50Hz to 5kHz

8000-6454-411

0.01% FSR

Analog and USB

4-channel (PP)

User Selectable 50Hz to 5kHz

8000-6454-412

0.01% FSR

Analog and USB

4-channel (180)

User Selectable 50Hz to 5kHz


ÍÆ¼ö×ÊѶ

  • RFSL2857ÉäÆµÍ¬Öá¸ôÀëÆ÷RFCI,3-3.5GHz
    RFSL2857ÉäÆµÍ¬Öá¸ôÀëÆ÷RFCI,3-3.5GHz 2025-05-21 08:59:48

    RFCIµÄRFSL2857ÉäÆµÍ¬Öá¸ôÀëÆ÷ÊÊÓÃÓÚ3000-3500MHz¸ßƵÐźŴ¦Àí£¬ÌṩÐźŸôÀëÒÔ·ÀÖ¹·´ÉäºÍ¸ÉÈÅ£¬µäÐͲåÈëËðºÄ<0.25dB£¬¸ôÀë¶ÈºÍ»Ø²¨ËðºÄ¾ù>23dB¡£Ö§³Ö1000W£¨·åÖµ£©/100W£¨Á¬Ðø£©Ç°Ïò¹¦ÂʺÍ1000W£¨·åÖµ£©/20W£¨Á¬Ðø£©·´Ïò¹¦ÂÊ£¬¹¤×÷ζÈ-40¡ãCÖÁ+85¡ãC¡£²ÉÓöÆÄø¸ÖÍâ¿ÇºÍ¶ÆÒøîëÍ­Òý½Å£¬³ß´çΪֱ¾¶19.0mm¡Á¸ß¶È6.5mm£¬Å䱸4¸ö2.5mm°²×°¿×ºÍ2¸ö2.0mm¼ä¾àÒý½Å£¬ÊÊÓÃÓÚͨÐÅÉ豸ºÍÀ×´ïϵͳµÈ¸ß¹¦ÂÊÓ¦Óá£

  • MTI Instruments Accumeasure OEMµçÈݰå
    MTI Instruments Accumeasure OEMµçÈݰå 2021-04-12 17:04:36

    MTI Instruments? AccumeasureMicro CapÊÇÒ»ÖÖСÐͶ¨ÖƵÄOEMµçÈݰ壬ÓÃ×÷¸ß¾«¶ÈµÄ·Ç½Ó´¥Ê½Î»ÒÆ¡¢±¡ºñºÍ¼ä϶¾«È·²âÁ¿¡£MTI Instruments AccumeasureMicro CapµçÈݰåÄܹ»Ñ¸ËÙ²¿ÊðOEM£¬ÕâÐèÒª¶¨Öƾ«È·²âÁ¿½â¾ö·½°¸£¬ÓÃ×÷΢¶¨Î»¡¢ÈÈУÕý¡¢¾Û½¹µãºÍ±Õ»·¿ØÖƼ¼ÊõÓ¦Óá£

ÔÚÏßÁôÑÔ

ÔÚÏßÁôÑÔ

¡¾ÍøÕ¾µØÍ¼¡¿¡¾sitemap¡¿